An IP66, dust and moisture resistant LED luminaire. Electronic, fixed output control gear with option to switch lumen output with two dip-switches on control gear. With medium beam distribution. Class I electrical. Canopy: light grey polycarbonate. Diffuser: high transmission opal polycarbonate with refraction prisms. Patented snap-on mechanism EasyClick for clipless mounting of diffuser. For surface or suspended mounting. Quick-fix brackets supplied for surface mounting. Suitable for ceiling or wall (both vertically and horizontally). Approved for indoor use or in canopied outdoor areas (see installation instructions). Mounting kits for conduit, chain suspension and catenary suspension are available as accessories. ambient temperature: 0°C to +40°C. Complete with 4000K LED. Luminaires will always be delivered with the highest configured lumen output. Please refer to installation instruction for detailed explanation of switchable lumen output..

Note: please contact your consultant if you are planning to use the luminaire in environments with chemical pollutants, high or condensing humidity and major variations in temperature.

Dimensions: 1600 x 92 x 90 mm
Luminaire input power: 43.6 W
Luminaire luminous flux: 6360 lm
Luminaire efficacy: 146 lm/W
Weight: 2 kg

Mode selection
  • Lamp position:6400 lm
  • Light Source:LED
  • Luminaire luminous flux*:6360 lm
  • Luminaire efficacy*:146 lm/W
  • Colour Rendering Index min.:80
  • Ballast:1 x 87500994 LC 50/200-350/170 flexC lp SNC4
  • Correlated colour temperature*:4000 Kelvin
  • Chromaticity tolerance (initial MacAdam):3
  • Rated median useful life*:L80 50000 h at 25 °C
  • Luminaire input power*:43.6 W Power factor = 0.96
  • Dimming:HFLS
  • Maintenance category CIE 97:E - Dust-proof IP5X
  • Total harmonic distortion (THD):11.00 %

Photometry

Photometric configuration

CalcExpress

Use CalcExpress to quickly carry out quick online calculations of required indoor luminaire numbers for rectangular rooms. Enter the calculation parameters for your solution such as room dimensions, mounting height, height of the useful plane and required level of illuminance, and the site will instantly suggest a solution according to the light output ratio method.